NonStop NS14000 Series Planning Guide (H06.13+)

Basic LAN Configuration
A basic dedicated service LAN that does not provide a fault-tolerant configuration requires
connection of these components to the ProCurve maintenance switch installed in the modular
cabinet:
One connection from the ME ENET port on each of the two VIO enclosures
One connection from slot 6B, port A on each of the two VIO enclosure for the OSM Service
Connection and OSM Notification Director
One connection to each of the optional UPS modules
One connection for each system console running OSM
This illustration shows a basic LAN configuration with one maintenance switch:
Figure 19 Basic LAN Configuration
Fault-Tolerant Configuration
Connect one system console to each maintenance switch.
Connect the VIO enclosure for the X fabric to one of the maintenance switches and the VIO
enclosure for the Y fabric to the other maintenance switch.
86 Maintenance and Support Connectivity