NonStop NS14000 Series Planning Guide (H06.13+)
Basic LAN Configuration
A basic dedicated service LAN that does not provide a fault-tolerant configuration requires
connection of these components to the ProCurve maintenance switch installed in the modular
cabinet:
• One connection from the ME ENET port on each of the two VIO enclosures
• One connection from slot 6B, port A on each of the two VIO enclosure for the OSM Service
Connection and OSM Notification Director
• One connection to each of the optional UPS modules
• One connection for each system console running OSM
This illustration shows a basic LAN configuration with one maintenance switch:
Figure 19 Basic LAN Configuration
Fault-Tolerant Configuration
• Connect one system console to each maintenance switch.
• Connect the VIO enclosure for the X fabric to one of the maintenance switches and the VIO
enclosure for the Y fabric to the other maintenance switch.
86 Maintenance and Support Connectivity