NonStop NS16000 Planning Guide (H06.08+)

Examples of Configurations
HP Integrity NonStop NS16000 Planning Guide529567-009
7-12
Example 16-Processor Triplex System Cabling
Components of the cable management system that are part of each modular enclosure
and the modular cabinet are not shown, so actual cable routing using is slightly
different from that shown. For detailed information on cable routing and connection as
part of the system installation, refer to the NonStop NS16000 Hardware Installation
Manual.
The next illustration shows the cabinets that house the modular I/O hardware and that
connect to the processor cabinets in the preceding illustration.
This illustration shows a simplified representation of the X and Y ServerNet cabling
between the IOAM enclosures and the p-switches, and the cabling between the FCSAs
and Fibre Channel disk modules. The example Fibre Channel disk module
configuration for the group 110 IOAM is a configuration of four-FCSAs and four Fibre
Channel disk modules shown in Four FCSAs, Four FCDMs, One IOAM Enclosure on
page 6-27. The example Fibre Channel disk modules for the group 111 IOAMs is a
daisy-chain configuration shown in Daisy-Chain Configurations on page 6-30.
From X Fabric
P-Switch, Slot 4
VST702.vsd
From Y Fabric
P-Switch, Slot 4
IOAM
111.3
IOAM
111.2
FCDM 4
FCDM 3
FCDM 2
FCDM 2
IOAM
110.3
IOAM
110.2
FCDM M2
FCDM P2
FCDM M1
FCDM P1
FCDM M2
FCDM P2
FCDM M1
FCDM P1
Cable Handler
From X Fabric
P-Switch, Slot 5
From Y Fabric
P-Switch, Slot 5