NonStop NS16000 Planning Guide (H06.08+)

Integrity NonStop NS16000 System Description
HP Integrity NonStop NS16000 Planning Guide529567-009
4-20
Modular Hardware
Modular Hardware
Hardware for Integrity NonStop NS16000 systems is implemented in modules
(enclosures installed in modular cabinets). For descriptions of the modular hardware
components, see Section 5, Modular System Hardware.
All Integrity NonStop NS16000 server components are field-replaceable units (FRUs)
that can only be serviced by service providers trained by HP.
For information about installing the Integrity NonStop NS16000 server hardware, refer
to the NonStop NS16000 Hardware Installation Manual.
NonStop S-Series I/O Hardware
Equipment from NonStop S-series systems can be connected to Integrity NonStop
NS16000 systems via fiber-optic ServerNet cables. This includes communications
adapters, disks with the data and applications stored on them, and tape devices in
NonStop S-series I/O enclosures equipped with IOMF 2 CRUs. The IOMF 2 CRUs
must have an MMF PIC for connection to fiber optic cables. For more information, see
NonStop S-Series I/O Enclosures on page 5-36.
System Models
The Integrity NonStop NS16000 is a model in the Integrity NonStop NS-series of
servers and includes:
Intel Itanium 1.6 GHz, 6-MB cache processors
16 processors maximum
4-GB, 8-GB, or 16-GB main memory per logical processor
16 or 32 DDR SDRAM DIMM slots
Note. Do not attempt to use NonStop S-series SEB or MSEB CRUs in NonStop S-series I/O
enclosures connected to Integrity NonStop NS16000 systems. SEB and MSEB CRUs are not
compatible with Integrity NonStop NS16000 systems.