NonStop NS16000 Planning Guide (H06.08+)
Modular System Hardware
HP Integrity NonStop NS16000 Planning Guide—529567-009
5-11
NonStop Blade Element
This illustration shows the rear of the NonStop Blade Element, equipped with two
power supplies and eight Blade optics adapters:
The numbers below the optics connectors refer to the processor numbers within the
NonStop Blade Element enclosure. Currently, only connectors J0, J1, J2, and J3 are
used. The remaining J connectors are for future use by the NonStop Blade Element
hardware.
Labels for the fiber-optic cable connections can become complex in a large system.
Fiber-optic cables for the ServerNet fabric and also the optic cable connections use the
same type of optics connector.
Because the modular hardware provides considerable flexibility in how the hardware is
distributed among multiple cabinets, a single cabinet could contain four NonStop Blade
Elements, with each NonStop Blade Element a member of a different NonStop Blade
Complex.
To reduce ambiguity in identifying proper cable connections to the NonStop Blade
Complex, the identification convention uses combinations of a letter to refer to each
connection. A number such as 0, 1, 2, and 3 identifies NonStop Blade Complexes, and
a letter such as A, B, or C identifies the NonStop Blade Element. Therefore, a single
NonStop Blade Element is identified with an alphanumeric ID, such as A1, A2, A3, and
so forth. These IDs refer to the appropriate NonStop Blade Element for proper
connection of the fiber-optic cables.
The optic cables provide communications between each NonStop Blade Element and
the LSU as well as between the LSU and the p-switch PICs on the X fabric and Y
fabric. No requirement exists to connect cables from a particular Blade optics adapter
on a NonStop Blade Element to a physically corresponding adapter on an LSU.
Caution. To maintain proper cooling air flow, blank panels must be installed in all slots that do
not contain Blade optics adapters.
AC Power
Connector
VST170.vsd
NonStop Blade Element
Enclosure (back)
Power Supply (2)
J Blade Optics
Adapters (cables
to LSU)
K Blade Optics
Adapters (cables
to LSU)
J1
J0
J3
J2
J5
J4
J7
J8
K1
K0
K3
K2
K5
K4
K7
K8
S T Q R
Reintegration
Connectors (cables
to peer NSBEs)