LSU Indicator LEDs
LSU Indicator LEDs
Processor Switch
The processor switch, or p-switch, provides the first level of ServerNet fabric
interconnect for the Integrity NonStop NS16000 processors. ServerNet connection
from the LSU also defines the ID numbers, 0 through 15, for the logical processors
within the system. In cases where NonStop S-series I/O enclosures provide I/O
capabilities and storage for the Integrity NonStop NS16000 system, the ServerNet
connection to the p-switch determines the NonStop S-series I/O enclosure group
number, as described in NonStop S-Series I/O Enclosure Group Numbers on
page 5-37.
Two p-switches are required, one each for the X and Y ServerNet fabrics. Physical
attributes for the 3U-high p-switch are:
•
Rackmountable
•
Dual AC power feeds and power supplies
•
Dual fans with front to rear cooling
•
Main logic board
•
Maintenance entity (ME) logic and firmware
•
Maintenance PIC (slot 1) for connection to maintenance switch
•
Cluster PIC (slot 2) for connection to 6770 or 6780 cluster switch
•
Crosslink PIC (slot 3) for connection to the other p-switch
LED State Meaning
LSU optics adapter
PIC (green LED)
Green Power is on; LSU is available for normal operation.
Off Power is off.
LSU optics adapter
PIC (amber LED)
Amber Power is in progress, board is being reset, or a fault
exists.
Off Normal operation or powered off.
LSU optics adapter
connectors (green
LEDs)
Green NonStop Blade Element optics link or ServerNet link is
functional.
Off Power is off, or a fault exists (amber LED is on).
LSU logic board
(green LED)
Green Power is on with LSU available for normal operation.
Off Power is off.
LSU logic board PIC
(amber LED)
Amber Power is in progress, board is being reset, or a fault
exists.
Off Normal operation or powered off.