NonStop NS16000 Series Planning Guide (H06.11+)
although it is not the PID. The same number is listed as the part number in OSM. Below is the
mapping for CLIM models and earliest supported RVUs:
Table 5 CLIM Models and RVU Requirements
Earliest Supported RVUName on LabelModel
For IP CLIMs: H06.16 and later RVUs414109-B21 or
453060-B21
DL385 G2 or G5
For Telco CLIMs: H06.18 and later RVUs
For Storage CLIMs: H06.20 and later RVUs
For IP CLIMs, either:494329-B21DL380 G6
• H06.17 through H06.20 RVUs with required SPRs listed in the
CLuster I/O Module (CLIM) Software Compatibility Reference
installed, or
• H06.21 and later RVUs
For Telco CLIMs, H06.18 and later RVUs
For IB CLIMs, H06.23 and later RVUs
For Storage CLIMs, either:
• H06.20 RVU with required SPRs listed in the CLuster I/O Module
(CLIM) Software Compatibility Reference installed, or
• H06.21 and later RVUs
The front of the DL385 G2 or G5 CLIM is shown below:
The front of the DL380 G6 CLIM is shown below:
These CLIM configurations are supported:
• “IP CLuster I/O Module (CLIM)” (page 116)
• “Telco CLuster I/O Module (CLIM)” (page 119)
• “IB CLuster I/O Module (CLIM) (Optional)” (page 121)
• “Storage CLuster I/O Module (CLIM)” (page 123)
The optional “CLIM Cable Management Ethernet Patch Panel” (page 122) cable management
product is a convenient way to configure Ethernet cables in a NonStop cabinet for IP and Telco
CLIMs.
IP CLuster I/O Module (CLIM)
The IP CLIM is a rack-mounted server that is part of some NonStop NS16000 series system
configurations. See Table 5 (page 116) for RVU and SPR requirements for DL385 G2 or G5 IP
CLIMs and DL380 G6 IP CLIMs. The IP CLIM functions as a ServerNet Ethernet adapter providing
116 Modular System Hardware