NonStop NS16000 Series Planning Guide (H06.11+)

Product IDLength in metersConnectorsCable TypeConnection From...
M8926–051.5RJ-45 to RJ-45CAT 5e UTP
(GESA external ports
support CAT 5e or
Maintenance LAN
interconnect
M8926–103
CAT 6 cables that you
provide.)
M8926–154.6
M8926–257.6
M8926–020.6RJ-45 to RJ-45CAT 6 UTP
(GESA external ports
support CAT 5e or
Maintenance LAN
interconnect
M8926–041.2
CAT 6 cables that you
provide.)
M8926–051.5
M8926–061.8
M8926–072.1
M8926–082.4
M8926–092.7
M8926–103
M8926–154.6
M8926–257.6
NOTE: ServerNet cluster connections on NonStop NS16000 series systems follow the ServerNet
cluster and cable length rules and restrictions. For more information, refer to these manuals:
ServerNet Cluster Supplement for NS-Series Systems
For 6770 switches and star topologies: ServerNet Cluster Manual
For 6780 switches and layered topology: ServerNet Cluster 6780 Planning and Installation
Guide
NOTE: BladeCluster connections on NonStop NS16000 series systems follow the BladeCluster
cable length rules and restrictions. For more information, refer to the BladeCluster Solutions Manual.
M8201R to Tape Device Cables
For SCSI cables connecting the M8201R Fibre Channel to SCSI router to tape drives, see the
M8201R Fibre Channel to SCSI Router Installation and User’s Guide.
Cable Management System
The cable management system (CMS) for Integrity NonStop NS16000 series systems contains
cable trays and vertical cable guides and is designed specifically for the Integrity NonStop
NS16000 series server components to manage all fiber cables, CAT 5e or CAT 6 cables, and for
some components and power cords. Using the CMS maintains the minimum 25mm bend radius
for the fiber cables and provides strain relief for the fiber-optic cables and the power cords. For
details on using the CMS, have your service provider refer to the NonStop NS16000 Series
Hardware Installation Manual.
154 Cables