NonStop NS16000 Series Planning Guide (H06.11+)
Figure 1 Slot and Connector Locations for the Processor Switch.
CLIM Connection Group-Module-Slot-Port Numbering
This table lists the default numbering for P-switch connections to a CLIM:
PIC Port NumbersP-Switch PIC Slot
2
ModuleCLIM Group
1
1-44 - 92100
1-44 - 93100
1
For RVU requirements for CLIMs, see Table 5 (page 116).
2
CLIMs can use slots 4 - 9. Networking CLIMs start with slot 9. Storage CLIMs start with slot 4. If slot 4 is needed for
S-series networking, CLIMs use slots 5 - 9.
IOAM Group-Module-Slot Numbering
These tables shows the default numbering for the IOAM enclosure:
PIC Port NumbersP-Switch PIC SlotIOAM Group
1-44110
1-45111
1-46112
1-47113
1-48114
1-49115
PortItemSlotY ServerNet
Module
X ServerNet
Module
IOAM Group
1 - n: where n is
number of ports on
adapter
ServerNet
adapters
1 to 532110 - 115 (See
preceding table.)
1 - 4ServerNet switch
logic board
14