NonStop NS16000 Series Planning Guide (H06.11+)
Four DL385 G2 or G5 Storage CLIMs, Four MSA70 SAS Disk Enclosures
This illustration shows example cable connections for the four DL385 G2 or G5 Storage CLIM,
four MSA70 SAS disk enclosures configuration:
Figure 16 Four DL385 G2 or G5 Storage CLIMs, Four MSA70 SAS Disk Enclosure Configuration
This table lists the Storage CLIM, LUN, and bay identification for the factory-default system disk
locations in the configuration of four DL385 G2 or G5 Storage CLIMs and four MSA70 SAS disk
enclosures. In this case, $SYSTEM, $DSMSCM, $AUDIT, and OSS are configured as mirrored
SAS disk volumes:
Mirror Disk Location
in Mirror SAS
Enclosure
Primary Disk
Bay in
Primary SAS
Enclosure
Mirror
LUN
Primay
LUN
Mirror-Backup
CLIM
Mirror
CLIM
Backup
CLIM
Primary
CLIM
Disk
Volume
Name
11101101100.2.5.3.3100.2.5.4.3100.2.5.4.1100.2.5.3.1$SYSTEM
22102102100.2.5.3.3100.2.5.4.3100.2.5.4.1100.2.5.3.1$DSMSCM
33103103100.2.5.3.3100.2.5.4.3100.2.5.4.1100.2.5.3.1$AUDIT
44104104100.2.5.3.3100.2.5.4.3100.2.5.4.1100.2.5.3.1$OSS
Daisy-Chain Configurations (DL385 G2 or G5 Storage CLIMs Only with MSA70 SAS Disk
Enclosures)
This illustration shows an example of cable connections for the two DL385 G2 or G5 Storage
CLIMs and four MSA70 SAS disk enclosures in a single daisy-chain configuration:
84 System Configuration Guidelines