NonStop NS16000 Series Planning Guide (H06.11+)
Two DL380 G6 Storage CLIMs, Four D2700 SAS Disk Enclosures
This illustration shows example cable connections for the two DL385 G2 or G5 Storage CLIM, four
D2700 SAS disk enclosures configuration. This configuration uses two SAS HBAs in slots 2 and
3 of each DL380 G6 Storage CLIM.
Figure 18 Two DL380 G6 Storage CLIMs, Four D2700 SAS Disk Enclosure Configuration
This table lists the Storage CLIM, LUN, and bay identification for the factory-default system disk
locations in the configuration of four DL380 G6 Storage CLIMs and two D2700 SAS disk enclosures.
In this case, $SYSTEM, $DSMSCM, $AUDIT, and OSS are configured as mirrored SAS disk
volumes:
Mirror Disk Location
in Mirror SAS
Enclosure
Primary Disk Bay in
Primary SAS
Enclosure
Mirror LUNPrimary
LUN
Backup and
Mirror CLIM
Primary and
Mirror-Backup
CLIM
Disk Volume
Name
11201101100.2.5.1100.2.4.1$SYSTEM
22202102100.2.5.1100.2.4.1$DSMSCM
33203103100.2.5.1100.2.4.1$AUDIT
44204104100.2.5.1100.2.4.1$OSS
For an illustration of the factory-default slot locations for a SAS disk enclosure, refer to
“Factory-Default Disk Volume Locations for SAS Disk Devices” (page 82).
Four DL380 G6 Storage CLIMs, Four D2700 SAS Disk Enclosures
This illustration shows example cable connections for the four DL380 G6 Storage CLIM, four D2700
SAS disk enclosures configuration. This configuration uses two SAS HBAs in slot 2 of each DL380
G6 Storage CLIM.
Storage CLIM Devices 87