NonStop Operations Guide for H-Series and J-Series RVUs

Figure 12 Processor Status Dialog Box
c. In the OSM Low-Level Link Processor Status dialog box, verify that all processors appear
in the Processor Status list.
d. Restart the OSM Low-Level Link application and then log on to the system.
NOTE: An already-running instance of the OSM Low-Level Link cannot be used here
because it may show incorrect processor status. Instead, restart the OSM Low-Level Link
application and log onto the system to start a new instance.
e. Click Processor Status.
f. Verify that all processors are listed in the Processor Status dialog box.
If a NonStop BladeSystem processor is still not listed, power cycle it by using OA
as described in “Power Cycling a NonStop BladeSystem Processor” (page 179).
If a NonStop NS2400 series, NS2300, NS2200 series, NS2100, or NS2000 series
processor is still not listed, power cycle it as described in “Power Cycling a NonStop
NS2000 Series, NS2100, NS2200 Series, NS2300, or NS2400 Series Processor
(page 181).
14. After the system is powered on, you must wait 5 minutes before starting the system.
15. You can now start your system as described in “Starting a System” (page 182).
Power Cycling a NonStop BladeSystem Processor
To use the Onboard Administrator (OA) to cycle power on a NonStop BladeSystem processor that
has not come up, do the following:
Powering On a System 179