NonStop Operations Guide for H-Series and J-Series RVUs
• In Chapter 16, added references to the new NS2200 system under:
“Powering On the System From a Low-Power State” (page 176)◦
◦ “Powering On the System From a No Power State” (page 177)
◦ “Starting a System” (page 182)
◦ “System Load Disks” (page 183)
◦ “Powering Off a System” (page 192)
• Changed and added steps for both NS2000 and NS2200 systems under “Power Cycling a
NonStop NS2000 Series, NS2100, NS2200 Series, NS2300, or NS2400 Series Processor”
(page 181).
• In Chapter 16 under “Starting a System” (page 182), changed text to indicate that only the
NonStop BladeSystems require a Halted State Services (HSS) firmware file on the dedicated
service LAN.
• In Chapter 16 under “System Load Disks” (page 183) and “Related Reading for Starting and
Stopping a System” (page 197), indicated that you should refer to the installation manual for
your system for instructions on how to create an alternate system disk.
New and Changed Information in 529869–018 Edition
This edition adds a table of contents to the beginning of the manual.
New and Changed Information in 529869–017 Edition
This edition includes support for the new NonStop NB54000c BladeSystem, which has a quad-core
microprocessor.
Change bars mark the following information, which has been added to or changed for this version
of the manual:
• Added NB54000c BladeSystems to “Determining Your System Configuration” (page 32) and
“NonStop BladeSystems NB50000c, NB50000c-cg, NB54000c, NB54000c-cg, NB56000c,
and NB56000c-cg Modular Hardware Components” (page 32) in Chapter 2.
• Added the Telco CLuster I/O Module (Telco CLIM) and the HP CLIM Cable Mangement Ethernet
patch panel to “NonStop BladeSystems NB50000c, NB50000c-cg, NB54000c, NB54000c-cg,
NB56000c, and NB56000c-cg Modular Hardware Components” (page 32) in Chapter 2.
• Changed text for the Serial attached SCSI (SAS) disk drive enclosure and added a reference
note under “NonStop BladeSystems NB50000c, NB50000c-cg, NB54000c, NB54000c-cg,
NB56000c, and NB56000c-cg Modular Hardware Components” (page 32) in Chapter 2.
• Changed references for the IP CLuster I/O Module (IP CLIM) and the Storage CLuster I/O
Module (Storage CLIM) under “NonStop NS-Series Modular Hardware Components” (page 34)
in Chapter 2.
• Added the Telco CLuster I/O Module (Telco CLIM) and the HP CLIM Cable Mangement Ethernet
patch panel to “NonStop NS-Series Modular Hardware Components” (page 34) in Chapter
2.
• Changed text for the Serial attached SCSI (SAS) disk drive enclosure and added a reference
note under “NonStop NS-Series Modular Hardware Components” (page 34) in Chapter 2.
• Added quad-core microprocessor to “Processors in NonStop Systems Running J-Series RVUs”
(page 121) in Chapter 10.
• Changed text for SAS disk drives under “Serial Attached SCSI (SAS) Disks and Solid State
Drives” (page 142) in Chapter 11.
18