Open System Services Installation Guide (H06.16+, J06.05+)
C OSS EasySetup Error Messages
The OSS EasySetup utilities can display these types of error messages:
• “Validation Check Errors”
• “Dialog Errors and Warnings” (page 50)
• “Break Key Message” (page 52)
Validation Check Errors
The utilities perform validation checks before doing anything else. If one of these checks fails, the
utility displays an error message and terminates:
Utilities That Perform This CheckCheck
All“Software RVU Check Error”
All“Remote Execution Check Error”
OSSSETUP“Home Terminal Check Error” (page 49)
OSSSETUP“$OSS Disk Volume Check Error” (page 50)
OSSSETUP“OSS Already Installed Check Error” (page 50)
Software RVU Check Error
ERROR - Unsupported software release...
Break or error terminated operation.
Startup of the OSS subsystem on \NODE1: FAILED
STARTOSS terminated unexpectedly or encountered errors.
Cause
The software RVU running on system-name does not support this utility. The utilities require
either the G06.15 software RVU (which includes the T0585AAA SPR) or the G06.12 (or later)
software RVU with the T0585AAA SPR installed.
Remote Execution Check Error
ERROR - Remote execution not supported...
Break or error terminated operation.
Startup of the OSS subsystem on \NODE1: FAILED
STARTOSS terminated unexpectedly or encountered errors.
Cause
You tried to run the utility utility-name from a remote system.
Home Terminal Check Error
ERROR - Unsupported home terminal session...
Break or error terminated operation.
Installation of the OSS subsystem on \NODE1: FAILED
OSSSETUP terminated unexpectedly or encountered errors.
Cause
Your home terminal session, $process.#device, is the wrong type (see “Required Terminal
Emulator” (page 15)).
Validation Check Errors 49