OSF DCE Problem Determination Guide

OSF DCE Problem Determination Guide
Action: See the open(2) manual page for further details.
0x10d0aa56 cds_s_server_pathbrokenevent
Severity: Notice Component: cds / cds_svc_server
Text: A lookup on parent directory %s failed.
Explanation: Server event ’Broken-Lookup-Paths’ has occurred. A lookup on the
directory name returned unknownentry.
Action: Make sure the server has read permissions on the directory. If the name has
changed, add a softlink pointing to the new directory name.
0x10d0aa59 cds_s_server_possiblecycleevent
Severity: Notice Component: cds / cds_svc_server
Text: A loop of softlinks exists for %s.
Explanation: Server event ’Possible-Cycle’ has occurred.
Action: Change the softlink target so a loop does not exist.
0x10d0aa35 cds_s_server_read
Severity: Error Component: cds / cds_svc_server
Text: Unable to read file %s: status = %ld.
Explanation: A call to the system function read(2) has failed.
Action: See the read(2) manual page for further details.
0x10d0aa41 cds_s_server_readchaddr
Severity: Warning Component: cds / cds_svc_server
Text: Could not read internal clearinghouse address: status = %ld.
Explanation: An unexpected error was detected while attempting to determine if the
clearinghouse address has changed.
Action: If the address of the clearinghouse has changed recently, restart the server at the
earliest opportunity. If this error persists, contact your DCE supplier.
0x10d0aa49 cds_s_server_rebuildindex_a
Severity: Fatal Component: cds / cds_svc_server
Text: Database index rebuild has failed: status = %s
Explanation: An attempt to rebuild a database index has failed. The server will dump
core.
Action: Restart the server.