OSF DCE Problem Determination Guide

Error Messages and Status Codes
0x1131f084 dcp_s_rpc_member_or_annot
Severity: Varies Component: dcp
Text: The ’-member’ can only be used with the ’-interface’ option.
Explanation: The -member option must be used with the -interface option, and cannot
be used with the -default, -priority,or -annotation options.
Action: Retype the command with proper options. See the documentation on the
rpcprofile remove command for the correct options.
0x1131f07f dcp_s_rpc_no_binding
Severity: Varies Component: dcp
Text: No string binding entered
Explanation: If an interface id is entered, then a string binding must be entered to be
exported for that interface.
Action: Retype the command with a string binding using the -binding option.
0x1131f07a dcp_s_rpc_no_binding_found
Severity: Varies Component: dcp
Text: No matching binding information found.
Explanation: No binding information could be found. Either none was found in the RPC
Entry, RPC Group, or RPC Profile, or none was found which matched criteria specified by
options.
Action: Either the name given was incorrect, or the options given were incorrect, or the
object does not contain any matching binding information. If either of the first two is the
case, retype the command correcting any incorrect values.
0x1131f074 dcp_s_rpc_no_entry_name
Severity: Varies Component: dcp
Text: No RPC Entry name given
Explanation: No RPC Entry name was given to the command.
Action: Retype the command with an RPC Entry name.
0x1131f075 dcp_s_rpc_no_group_name
Severity: Varies Component: dcp
Text: No RPC Group name given
Explanation: No RPC group name was given to the command.
Action: Retype the command with an RPC Group name.
124330 Tandem Computers Incorporated 2173