OSF DCE Problem Determination Guide

OSF DCE Problem Determination Guide
0x115ca058 dts_s_dce_error
Severity: Error Component: dts / dts_s_events
Text: DCE error %s
Explanation: DCE error occurred.
Action: Verify DCE operation and configuration.
0x115ca04e dts_s_different_epoch
Severity: Warning Component: dts / dts_s_general
Text: Current epoch %d, differs from epoch %d of server %s
Explanation: While attempting a synchronization, a server encountered a server whose
epoch number did not match its own. The clock value from this differing server was
ignored.
Action: Verify the epoch number of the server by using the dts show command. To
change a server’s epoch number issue the command clock set -epoch integer.
0x115ca03e dts_s_dtsdate_usage
Severity: Error Component: dts / dts_s_dtsdate
Text: Usage: dtsdate [-s] [-q] [-u] hostname [skew-seconds]
Explanation: This is the appropriate set of command line arguments
Action: Re-run command with appropriate arguments
0x115ca024 dts_s_dtsd_comm
Severity: Varies Component: dts
Text: Cannot contact dts daemon - rpc failure:
Explanation: An attempt was made to restart the DTS daemon; however, an rpc error
occurred.
Action: Make sure that the dts daemon is running: if not, see the DTS Administration
documentation on how to restart
0x115ca068 dts_s_entry_object_inq_begin
Severity: Error Component: dts / dts_s_error
Text: Couldn’t retrieve UUID for server %s from the namespace: %s
Explanation: An attempt to retrieve the server’s UUID failed
Action: Check the namespace for errors
0x115ca067 dts_s_entry_object_inq_next
Severity: Error Component: dts / dts_s_error
2 202 Tandem Computers Incorporated 124330