Error Messages and Status Codes
Explanation: The security call to automatically change a principal’s key before it expires
failed
Action: This is a RPC security error. Check RPC status codes for more information
0x115ca0b1 dts_s_security_init
Severity: Error Component: dts / dts_s_error
Text: Error retrieving security configuration information: %s
Explanation: An error occurred when retrieving the security configuration information
for the dts daemon
Action: Fix and restart the daemon
0x115ca080 dts_s_select_strbind
Severity: Warning Component: dts / dts_s_error
Text: Couldn’t select a string binding for the Time Provide Interface: %s
Explanation: The dtsd couldn’t create a string binding for a local Time Provider interface
Action: This is an RPC error. Check RPC errors for more info
0x115ca0a8 dts_s_server_only
Severity: Warning Component: dts / dts_s_error
Text: The attribute %s is not settable when dtsd is running as a clerk\n
Explanation: Certain variables can only be set when dtsd is running as a server.
Action: Remove this variable from the set of configuration attributes
0x115ca07f dts_s_server_reg_auth_info
Severity: Error Component: dts / dts_s_error
Text: Couldn’t register server authentication info: %s
Explanation: An attempt to register the server authentication info failed
Action: This is a security error. Check security errors for more information
0x115ca007 dts_s_servers_range
Severity: Varies Component: dts
Text: Server value out of range
Explanation: An attempt was made to set the minservers attribute; however, the value
was not within the legal range
Action: Retry the command using a value from 1-10 for the minservers attribute. It is
recommended that you set the value to 3 or more. The default setting is 3. A smaller value
wil cause the synchronized time to be a less reliable measure of the Coordinated
Universal Time (UTC).