OSF DCE Problem Determination Guide

Error Messages and Status Codes
Text: An invalid audit trail descriptor was used
Explanation: The user invoked the Audit routines using an invalid at value.
Action: Use a valid audit trail descriptor.
0x1032306e aud_s_line_too_long_in_class_file
Severity: Error Component: aud / aud_s_general
Text: A line is too long in event class file %s
Explanation: A line in the event class file exceeds 2K.
Action: Check the event class file. Correct the line length and retry the operation.
0x10323055 aud_s_lock_esl_file
Severity: Notice Component: aud / aud_s_esl
Text: Cannot lock file %s
Explanation: For various reasons (for example, file may be locked by others), the file
cannot be locked.
Action: None required.
0x10323036 aud_s_log_access_denied
Severity: Error Component: aud / aud_s_general
Text: Client’s audit log access denied
Explanation: A client attempted to log to the audit record; however, the client is not
authorized to perform this operation.
Action: Check if the client should be authorized. Modify the ACL of the Audit daemon,
if necessary.
0x10323073 aud_s_no_current_login_context
Severity: Error Component: aud / aud_s_general
Text: Cannot get login context
Explanation: The dce_login command has not been performed and is required by the
requested operation.
Action: Execute the dce_login command.
0x10323072 aud_s_no_filter
Severity: Notice Component: aud / aud_s_esl
Text: No filter was found for the subject.
Explanation: This is an informational message.
124330 Tandem Computers Incorporated 2 21