OSF DCE Problem Determination Guide

Error Messages and Status Codes
0x1260a190 GDS_S_SIGNAL_ERR
Severity: Fatal Component: gds / GDS_S_GENERAL
Text: Signal %d terminates process.
Explanation: The program has received the specified signal.
Action: The signal is either sent to the process by the system (e. g. segmentation
violation) or by a user. Report the problem to the responsible software engineer. in the
first case. Forbid the user to send signals in the second case. Reactivate the system.
0x1260aa90 GDS_S_SRT_NNAM_AT_ERR
Severity: Fatal Component: gds / GDS_S_GENERAL
Text: Invalid acronym %s for structure rule table.\n
Explanation: The Structure Rule Table (SRT) of the administrated schema is in an illegal
state. It contains an entry having an acronym for the naming attribute, which is not found
in the attribute table (AT).
Action: This problem may occur due to a change to the schema object by an application
program, that did not use the schema administration of GDS. The error is fatal for
gdsgendb but not for gdsdsa, which continues with the unchanged schema. No action
required. The problem may also occur, when a corrupted database is restored. In this case
it is fatal for the gdsdsa. A consistent database has to be restored in this case.
0x1260aa92 GDS_S_SRT_NSTR_OC_ERR
Severity: Fatal Component: gds / GDS_S_GENERAL
Text: Invalid acronym %s for object class.\n
Explanation: The Structure Rule Table (SRT) of the administrated schema is in an illegal
state. It contains an entry having an acronym for an object class, which is not a structural
object class.
Action: This problem may occur due to a change to the schema object by an application
program, that did not use the schema administration of GDS. The error is fatal for
gdsgendb but not for gdsdsa, which continues with the unchanged schema. No action
required. The problem may also occur, when a corrupted database is restored. In this case
it is fatal for the gdsdsa. A consistent database has to be restored in this case.
0x1260aa91 GDS_S_SRT_OC_INVALID
Severity: Fatal Component: gds / GDS_S_GENERAL
Text: Unknown acronym %s for object class.\n
Explanation: The Structure Rule Table (SRT) of the administrated schema is in an illegal
state. It contains an entry having an acronym for an object class, which is not found in the
object class (OCT).
Action: This problem may occur due to a change to the schema object by an application
program, that did not use the schema administration of GDS. The error is fatal for
gdsgendb but not for gdsdsa, which continues with the unchanged schema. No action
124330 Tandem Computers Incorporated 2331