OSF DCE Problem Determination Guide

Error Messages and Status Codes
0x1260a962 GDS_S_SUP_USAGE
Severity: Fatal Component: gds / GDS_S_GENERAL
Text: The gdsdaemon program was called with wrong syntax.\n
Explanation: The program gdsdaemon was started with illegal parameters.
Action: Start the program again with the correct syntax: gdsdaemon -ddir-id -mop-mode
[-njob-entry] [-vSVC-logging] [-wSVC]
0x1260a970 GDS_S_SUP_WR_HEADER_INFO
Severity: Fatal Component: gds / GDS_S_GENERAL
Text: The program could not write the header information to file %s, errno = %d.\n
Explanation: The program gdsdaemon could not write header information to a
temporary file.
Action: Evaluate errno for the reason. Report the problem to the responsible software
engineer.
0x1260a97b GDS_S_SUP_WRITE_LOG_ERR
Severity: Fatal Component: gds / GDS_S_GENERAL
Text: The program could not write the logmessage, errno = %d.\n
Explanation: The program gdsdaemon could not write the logmessage into the
shadowlogfile.
Action: Evaluate errno for the reason. Report the problem to the responsible software
engineer.
0x1260a963 GDS_S_SUP_WRONG_OPMODE
Severity: Fatal Component: gds / GDS_S_GENERAL
Text: The gdsdaemon program was started with an illegal operation mode %d.\n
Explanation: The program gdsdaemon was started with an illegal operation mode. Only
mode 1 or 2 are supported.
Action: Start the program again with a valid operation mode.
mode do distribution of \L*SHDLOG file only
mode do distribution of \L*SHDLOG file and all required delta update operations
0x1260a0e6 GDS_S_SYSTEM_ERR
Severity: Warning Component: gds / GDS_S_GENERAL
Text: A call to system has failed, errno = %d.
Explanation: The program could not call ’system’.
Action: Evaluate errno for the reason. Depending on the reason, possible actions are:
124330 Tandem Computers Incorporated 2337