OSF DCE Problem Determination Guide

Error Messages and Status Codes
Explanation: Specified password is shorter than the current minimum limit.
Action: Specify a longer password.
0x1712208b sec_rgy_quota_exhausted
Severity: Varies Component: sec
Text: Principal quota exhausted
Explanation: Principal’s registry quota is exhausted and an update operation was
attempted.
Action: Ensure that correct identity is used to perform operation. Increase quota if
necessary.
0x17122082 sec_rgy_read_only
Severity: Varies Component: sec
Text: Registry is read only - updates are not allowed
Explanation: Registry is in a read only state and an update was attempted.
Action: Wait until registry is no longer in a read only state, then retry.
0x17122e80 sec_rgy_rep_add_master_replica
Severity: Fatal Component: sec / sec_s_rs_rep
Text: Error adding master replica to an uninitialized database\n%s
Explanation: When a slave database is re-initializing, in-memory data is cleared and re-
created. Problem occurred when trying to add master replica to its database.
Action: ?
0x17122e7f sec_rgy_rep_add_my_replica
Severity: Fatal Component: sec / sec_s_rs_rep
Text: Error adding my replica to an uninitialized database\n%s
Explanation: When a slave database is re-initializing, in-memory data is cleared and re-
created. Problem occurred when trying to add this slave replica to its database.
Action: ?
0x171220c9 sec_rgy_rep_already_inited
Severity: Varies Component: sec
Text: slave already initialized
Explanation: Attempt to initialize a replica that has already been initialized.
Action: None required.
124330 Tandem Computers Incorporated 2603