OSF DCE Problem Determination Guide

OSF DCE Problem Determination Guide
Text: Replica is the master
Explanation: Specified operation may only be performed at a non-master registry replica
site.
Action: None required.
0x171220cb sec_rgy_rep_master_bad_sw_vers
Severity: Varies Component: sec
Text: master is running a bad software version
Explanation: Master registry is running a version of software that is not compatible with
the replica registry servers.
Action: Ensure that the correct version of sw is being used.
0x171220cd sec_rgy_rep_master_dup
Severity: Varies Component: sec
Text: duplicate masters
Explanation: Duplicate master registry servers found.
Action: Ensure that only one master registry server exists for this cell.
0x171220b0 sec_rgy_rep_master_not_found
Severity: Varies Component: sec
Text: cannot find master
Explanation: A registry replica was unable to locate the master registry.
Action: Ensure the master registry is up and accessible.
0x17122e4b sec_rgy_rep_master_obsolete
Severity: Fatal Component: sec / sec_s_rs_rep
Text: Master’s database is probably obsolete\n%s
Explanation: A slave has a higher update sequence number than this master, which
implies this master has an obsolete database; so exit itself.
Action: ?
0x17122e79 sec_rgy_rep_mst_restart_prop
Severity: Fatal Component: sec / sec_s_rs_rep
Text: Master cannot restart prop tasks when change_master failed\n%s
Explanation: After change_master operation failed, the old master try to resume its
master role but fail to restart its propagation task threads.
2 608 Tandem Computers Incorporated 124330