OSF DCE Problem Determination Guide

OSF DCE Problem Determination Guide
Explanation: This code won’t be executed; we may as well take it out :-) or replaced
with same fatal message
Action: ?
0x17122e7b sec_rgy_rep_set_state
Severity: Fatal Component: sec / sec_s_rs_rep
Text: Cannot set replica state\n%s
Explanation: This code won’t be executed; we may as well take it out :-) or replaced
with same fatal message
Action: ?
0x17122e7d sec_rgy_rep_set_volatile_state
Severity: Fatal Component: sec / sec_s_rs_rep
Text: Cannot save volatile replica state\n%s
Explanation: This code won’t be executed; we may as well take it out :-) or replaced
with same fatal message
Action: ?
0x171220cc sec_rgy_rep_slave_bad_sw_vers
Severity: Varies Component: sec
Text: slave is running a bad software version
Explanation: Replica registry server is running a version of software that is not
compatible with the master registry server.
Action: Ensure that the correct version of sw is being used.
0x17122e7a sec_rgy_rep_slv_restart_prop
Severity: Fatal Component: sec / sec_s_rs_rep
Text: Master cannot restart prop tasks when become_slave failed\n%s
Explanation: After become_slave operation failed, the old master try to resume its
master role but fail to restart its propagation task threads.
Action: ?
0x171220ba sec_rgy_rep_update_seqno_high
Severity: Varies Component: sec
Text: slave must have missed/lost some update from master
Explanation: Slave must have missed/lost some update from the master.
Action: If problem does not correct itself with propagations from the master, then the
replica may need to be initialized with a security administration tool.