Pathway/iTS Web Client Programming Manual (H06.03+, J06.03+)
Table Of Contents
- HP NonStop Pathway/iTS Web Client Programming Manual
- Legal Notices
- Contents
- What's New in This Manual
- About This Manual
- 1 Introduction to Pathway/iTS Web Clients
- 2 How to Compile, Build, and Maintain a Pathway/iTS Web Client
- 1. Prepare the SCREEN COBOL Object File
- 2. Create a Configuration File
- 3. Run the Converter
- 4. Modify Java or SCREEN COBOL Code as Needed
- 5. Run PROFDBM to Set Up the User Profile Database
- 6. Build the Converted Client
- 7. Deploy the Web Client
- 8. Customize the Screens
- 9. Specify the Port Number of the Router Process
- 10. Configure Pathway Servers for User Profiles and User Conversion Routines
- 11. Tune the Application for Performance by Changing the Session-Length Parameter
- 12. Maintain the Client
- 3 Logon Security and User Profiles
- 4 User-Written User Conversion Procedures for Web Clients
- 5 SCREEN COBOL-to-Web Conversion Mappings
- 6 Java Import Package Reference
- 7 Introduction to Pathway/iTS 1.1
- A Client Error Messages
- B SCREEN COBOL Features Not Supported for Web Conversion
- Index
- Content Feedback

Client Error Messages
HP NonStop Pathway/iTS Web Client Programming Manual—520270-003
A-2
Message Descriptions
3003
Cause. The value of a subscript expression was either zero or larger than the limit
implied by the OCCURS clause.
Effect. The applet stops.
Recovery. Isolate and correct the problem within the Java program, using the stack
trace information in
error-loc
to locate the problem. Alternatively, correct the
problem in the SCREEN COBOL program and reconvert the application.
3005
Cause. The number of parameters passed in the USING clause of a CALL statement
was not equal to the number of parameters given in the Procedure Division header of
the called program.
Effect. The applet stops.
Recovery. Isolate and correct the problem within the Java program, using the stack
trace information in
error-loc
to locate the problem. Alternatively, correct the
problem in the SCREEN COBOL program and reconvert the application.
3006
Cause. The maximum size of a parameter passed in the USING clause of a CALL
statement was not equal to the maximum size of the corresponding parameter given in
the Procedure Division header of the called program.
Effect. The applet stops.
Recovery. Isolate and correct the problem within the Java program, using the stack
trace information in
error-loc
to locate the problem. Alternatively, correct the
problem in the SCREEN COBOL program and reconvert the application.
*3003* INVALID SUBSCRIPT VALUE
error-loc
*3005* CALL: ACTUAL NUMBER OF PARAMETERS MISMATCHES FORMAL
error-loc
*3006* CALL: ACTUAL PARAMETER SIZE MISMATCHES FORMAL
error-loc