Pathway/iTS Web Client Programming Manual (H06.03+, J06.03+)
Table Of Contents
- HP NonStop Pathway/iTS Web Client Programming Manual
- Legal Notices
- Contents
- What's New in This Manual
- About This Manual
- 1 Introduction to Pathway/iTS Web Clients
- 2 How to Compile, Build, and Maintain a Pathway/iTS Web Client
- 1. Prepare the SCREEN COBOL Object File
- 2. Create a Configuration File
- 3. Run the Converter
- 4. Modify Java or SCREEN COBOL Code as Needed
- 5. Run PROFDBM to Set Up the User Profile Database
- 6. Build the Converted Client
- 7. Deploy the Web Client
- 8. Customize the Screens
- 9. Specify the Port Number of the Router Process
- 10. Configure Pathway Servers for User Profiles and User Conversion Routines
- 11. Tune the Application for Performance by Changing the Session-Length Parameter
- 12. Maintain the Client
- 3 Logon Security and User Profiles
- 4 User-Written User Conversion Procedures for Web Clients
- 5 SCREEN COBOL-to-Web Conversion Mappings
- 6 Java Import Package Reference
- 7 Introduction to Pathway/iTS 1.1
- A Client Error Messages
- B SCREEN COBOL Features Not Supported for Web Conversion
- Index
- Content Feedback

Client Error Messages
HP NonStop Pathway/iTS Web Client Programming Manual—520270-003
A-5
Message Descriptions
present in the Java code—then the ON ERROR branch is taken. Otherwise, the applet
stops.
Recovery. Either configure TMF auditing or isolate and correct the problem within the
Java program, using the stack trace information in
error-loc
to locate the problem.
Alternatively, correct the problem in the SCREEN COBOL program and reconvert the
application.
3031
Cause. An attempt to use the Transaction Management Facility (TMF) failed because
the TMF software was not running on the host NonStop system.
Effect. If the ON ERROR clause of the BEGIN-TRANSACTION statement is present
in the SCREEN COBOL source code—that is, if the onTxnErrorMethod method is
present in the Java code—then the ON ERROR branch is taken. Otherwise, the applet
stops.
Recovery. Either configure TMF auditing or isolate and correct the problem within the
Java program, using the stack trace information in
error-loc
to locate the problem.
Alternatively, correct the problem in the SCREEN COBOL program and reconvert the
application.
3037
Cause. An illegal timeout value was used in an ACCEPT statement. The value was
either less than zero or too large to be represented in an INT(32) field.
Effect. The operation fails and the applet stops.
Recovery. Isolate and correct the problem within the Java program, using the stack
trace information in
error-loc
to locate the problem. Alternatively, correct the
problem in the SCREEN COBOL program and reconvert the application.
3040
Cause. The screen field referenced in a verb does not contain numeric data.
Effect. The applet stops.
Recovery. Isolate and correct the problem within the Java program, using the stack
trace information in
error-loc
to locate the problem. Alternatively, correct the
problem in the SCREEN COBOL program and reconvert the application.
*3031* TMF NOT RUNNING
error-loc
*3037* ILLEGAL ACCEPT VARIABLE TIMEOUT VALUE
error-loc
*3040* INVALID NUMERIC ITEM
error-loc










