Pathway/iTS Web Client Programming Manual (H06.03+, J06.03+)
Table Of Contents
- HP NonStop Pathway/iTS Web Client Programming Manual
- Legal Notices
- Contents
- What's New in This Manual
- About This Manual
- 1 Introduction to Pathway/iTS Web Clients
- 2 How to Compile, Build, and Maintain a Pathway/iTS Web Client
- 1. Prepare the SCREEN COBOL Object File
- 2. Create a Configuration File
- 3. Run the Converter
- 4. Modify Java or SCREEN COBOL Code as Needed
- 5. Run PROFDBM to Set Up the User Profile Database
- 6. Build the Converted Client
- 7. Deploy the Web Client
- 8. Customize the Screens
- 9. Specify the Port Number of the Router Process
- 10. Configure Pathway Servers for User Profiles and User Conversion Routines
- 11. Tune the Application for Performance by Changing the Session-Length Parameter
- 12. Maintain the Client
- 3 Logon Security and User Profiles
- 4 User-Written User Conversion Procedures for Web Clients
- 5 SCREEN COBOL-to-Web Conversion Mappings
- 6 Java Import Package Reference
- 7 Introduction to Pathway/iTS 1.1
- A Client Error Messages
- B SCREEN COBOL Features Not Supported for Web Conversion
- Index
- Content Feedback

Client Error Messages
HP NonStop Pathway/iTS Web Client Programming Manual—520270-003
A-18
Message Descriptions
Recovery. Check the Pathway log file for any error message related to failure in the
start of a transaction. Isolate and correct the problem within the Java program, using
the Pathway log file and the stack trace information in
error-loc
to locate the
problem. Alternatively, correct the problem in the SCREEN COBOL program and
reconvert the application.
3308
Cause. The applet got error while loading an HTML page for already loaded base
screen.
Effect. The operation fails.
Recovery. Check the stack trace to find where the URL path got corrupted.
3310
Cause. The IS NUMERIC clause was called for a computational data item. The data
item cannot be computational.
Effect. The applet stops.
Recovery. Isolate and correct the problem within the Java program, using the stack
trace information in
error-loc
to locate the problem. Alternatively, correct the
problem in the SCREEN COBOL program and reconvert the application.
3311
Cause. An error occurred while retrieving user profile data from the profile database
server.
Effect. The applet does not start.
Recovery. Check the Java console for additional information the problem. Isolate and
correct the problem within the Java program. Alternatively, correct the problem in the
SCREEN COBOL program and reconvert the application. Follow the guidelines in
Section 3, Logon Security and User Profiles, on how to set up the user profile database
and server.
*3308* SPECIFIED URL FORMAT IS INVALID
*3310* EXPECT DISPLAY USAGE
error-loc
*3311* USER PROFILE SERVER COMMUNICATION ERROR