RDF System Management Manual for H-Series and J-Series RVUs (RDF 1.9)
Additionally, the STATUS RDF display has been enhanced to identify which database volumes
are still being synchronized. That information is reported in the error column of the display. If
a volume is still being synchronized, its entry in the error column is sync. As soon as a volume
is successfully synchronized, its entry in the error column is blank. If an updater encounters an
error during synchronization, the associated entry in the error column is ****.
The following sample display shows that the updater process $MUP1 for the data volume
$DATA1 has successfully completed synchronization while the updater process $MUP2 for the
data volume $DATA2 is still doing the synchronization:
RDF Process Name RTD Time Pri Volume Seqnce Rel Byte Addr Cpus Err
------------------ ------ --------- --- ------- ------ ------------- ----- ----
Monitor $MMON 185 $TRAILS 5 2: 3
Extractor (0) $MEXT 0:00 185 $TRAILS 5 7110636 1: 2
Receiver (0) $MRCV 0:00 185 $TRAILS 37 806912 1: 2
$DATA06 -> $DATA06 $MUP1 0:00 185 $TRAILS 37 806912 1: 2
$DATA07 -> $DATA07 $MUP2 1:59 185 $TRAILS 32 712704 2: 3 sync
Determining When Online Database Synchronization Is Complete 185