RDF System Management Manual for H-Series and J-Series RVUs (RDF 1.9)

Cause The COPYAUDIT command could not find any image files on the remote image trail.
This problem indicates that the receivers RETAINCOUNT value was probably not set high
enough and that, as a result, some image files on the remote system were purged.
Effect The COPYAUDIT command aborts.
Recovery There is no recovery action. The COPYAUDIT command cannot be executed
because image files needed for this command were already purged from the remote system.
No MONITOR is Configured
Cause The RDF configuration file is invalid.
Effect The validation fails.
Recovery Alter the configuration to include the monitor.
No PCB available
Cause A NEWPROCESS error occurred during START RDF or TAKEOVER processing.
Effect The command fails.
Recovery Check system resource utilization. When resources become available, reenter the
command.
No RECEIVER is Configured
Cause The RDF configuration file is invalid.
Effect The configuration validation fails.
Recovery Check the receiver parameter entries in the configuration file for invalid values
and correct any errors found.
No VOLUMEs are configured
Cause The RDF configuration file is invalid.
Effect The configuration validation fails.
Recovery Check the updater process parameters in the configuration file for invalid values
and correct any errors found.
No VOLUMES are configured for ATINDEX atindex
Cause You added an extractor and receiver with the specified ATINDEX, but there are no
updaters with that value.
Effect The validation fails.
Recovery Add at least one updater with the same ATINDEX value or delete the particular
extractor-receiver pair.
Obtained error error# in attempting to examine remote imagetrail files
error#
is the file-system error number that identifies the specific error.
Cause The COPYAUDIT command encountered the specified error in attempting to read
the remote image trail files.
Effect The command fails.
Recovery See the Operator Messages Manual for a description of the error code. For additional
details about understanding and correcting file-system errors, see the Guardian Procedure Errors
and Messages Manual. If possible, correct the error and reenter the COPYAUDIT command.
Otherwise, see your system manager.
Only one Network record is allowed for a non-network master
Cause Your current RDF configuration does not have the NetworkMaster attribute set and
you have tried to add more than one network record.
Effect The configuration command fails.
RDFCOM Messages 433