Cause While searching for a TMF shutdown timestamp to use to initialize RDF, RDFCOM
found that the audit trail file with the specified sequence number is not currently available.
If you respond to the prompt with YES or Y, RDFCOM directs the TMP to begin restoring this
file.
NOTE: If the file was dumped to tape, you must wait for the TMP to prompt you to mount
the tape. This mount request is logged in the EMS log.
If you respond with NO or N, then RDFCOM aborts the initialization attempt.
Effect RDFCOM waits for your response to the prompt.
Recovery Respond YES or Y, or NO or N, to the prompt.
The MONITOR must be a named process.
Cause You must specify a process name for the monitor process before issuing an ADD
command.
Effect The start command fails.
Recovery You must reconfigure RDF with the named monitor process.
The number of physical UPDATEVOLUMES exceeds 255. RDF/IMPX is required
for this many volumes.
Cause RDF has detected that the user is running RDF/IMP and the total number of physical
volumes for all UPDATEVOLUMEs exceeds 255. This can happen where some, or all, of the
UPDATEVOLUMEs are SMF virtual disks.
Effect RDF will not start.
Recovery Upgrade the RDF software to RDF/IMPX or reconfigure your disks on the RDF
backup node so that the total number of physical disks for all the UPDATEVOLUMEs is less
than 255.
The PURGER must be a named process
Cause You must specify a process name for the purger process before issuing an ADD
command.
Effect The start command fails.
Recovery You must reconfigure RDF with a named purger process.
The RDF primary system in the environment you are attempting to copy
audit from does not match the primary system in this environment.
Cause The COPYAUDIT command detected that the RDF primary system in the RDF
environment you are attempting to copy audit from is not the same as the RDF primary system
in the local environment.
Effect The COPYAUDITcommand aborts.
Recovery Correct the REMOTESYS remote-sys and REMOTECONTROLSUBVOL rcvs
parameters and reissue the COPYAUDIT command.
RDFNET must be a named process
Cause You must specify a process name for the RDFNET process before issuing an ADD
command.
Effect The start command fails.
Recovery You must reconfigure RDF with a named RDFNET process.
"The remote control subvolume\bksys.$SYSTEM.subvol is not empty. The
files on the remote control subvolume must be purged. Please note, these
files might belong to another RDF configuration.