RDF System Management Manual for J-series and H-series RVUs (RDF 1.10)
Effect
The ADD EXTRACTOR command fails.
Recovery
Review and revise your RDF configuration.
Maximum number of image trails already added
Cause
You have already added the maximum number of secondary image trails (255), and cannot
add more.
Effect
The command fails.
Recovery
No recovery action is possible; your RDF subsystem can only support 256 secondary image
trails.
Missing network master NETWORK record
Cause
No network record exists that corresponds to the network master subsystem.
Effect
RDF does not start.
Recovery
Add a network record to describe the network master subsystem.
MONITOR Record exists, use ALTER MONITOR
Cause
An ADD MONITOR command was issued when the configuration file already contained a
monitor record.
Effect
The command fails.
Recovery
No recovery is required if you want to use the existing monitor process as configured. If you
want to change any of the monitor’s configuration options, however, enter an ALTER MONITOR
command that specifies those changes.
MONITOR record NOT found
Cause
The INFO command could not find a monitor record in the configuration file.
Effect
The command fails.
Recovery
Alter the configuration to include the monitor process.
Network options are only available with the RDF/IMPX product
Cause
You have attempted to specify configuration information for an RDF network, but you do not
have an RDF/IMPX license.
Effect
The configuration command fails.
RDFCOM Messages 433