RDF System Management Manual for J-series and H-series RVUs (RDF Update 13)
Recovery
Either the file was not created by the lockstep process, or the audit attribute was erroneously
turned off. Purge the file and restart the lockstep gateway.
12
Invalid message-id msgid returned from RDF extractor procname with
ATINDEX indexnum.
msgid
is the invalid message id.
procname
is the name of an RDF extractor process.
indexnum
is the audit trail index number of the specified extractor.
Cause
The lockstep gateway sent a request to the RDF extractor, and the latter returned the included
message id number.
Effect
The lockstep gateway stops.
Recovery
This is an internal error, but the gateway is restarted. If the problem persists, contact the Global
Mission Critical Solution Center (GMCSC) or your service provider.
13
Invalid data returned from the RDF extractor procname with ATINDEX
indexnum.
procname
is the name of an RDF extractor process.
indexnum
is the audit trail index number of the specified extractor.
Cause
The lockstep gateway sent a request to the RDF extractor, and the latter returned invalid data.
Effect
The lockstep gateway stops.
Recovery
This is an internal error, but the gateway is restarted. If the problem persists, contact the Global
Mission Critical Solution Center (GMCSC) or your service provider.
14
BEGINTRANSACTION error errnum when attempting a lockstep transaction.
errnum
is a file-system error number.
Cause
The gateway encountered the specified error on BEGINTRANSACTION.
Effect
If the error is retryable, the lockstep gateway starts a new transaction. If the error is unexpected,
the gateway stops.
Lockstep Gateway Event Messages 309