RDF System Management Manual for J-series and H-series RVUs (RDF Update 13)

Cause
The lockstep gateway is started.
Effect
The lockstep gateway continues its initialization activity.
Recovery
This is an informational message; no recovery is required.
28
RDF extractor procname with ATINDEX indexnum responded with error errnum
to lockstep request.
procname
is the name of an extractor process.
errnum
is a file-system error number.
indexnum
is the audit trail index number of the specified extractor.
Cause
While the extractor is processing a lockstep request, the gateway stops, has been restarted by
SCF, and has sent a new lockstep request to the extractor.
Effect
The lockstep gateway stops.
Recovery
SCF automatically restarts the gateway. If the problem persists and the autorestart count is
exhausted, wait 30 seconds and then restart the gateway again.
29
Lockstep transaction aborted with error errnum.
errnum
is a file-system error number.
Cause
The specified error was encountered on a lockstep transaction.
Effect
If the error is retryable, the lockstep gateway starts a new transaction. If the error is unexpected,
the gateway stops.
Recovery
This is an informational error, unless the gateway stops. If it stops, correct the condition that
caused the error and then restart the gateway.
30
ENDTRANSACTION error errnum encountered on lockstep transaction.
errnum
is a file-system error number.
Cause
The specified error was encountered on ENDTRANSACTION.
314 Process-Lockstep Operation