RDF System Management Manual for J-series and H-series RVUs (RDF Update 13)
filename can be a spooler location or a file. In case of a file, it must be an EDIT
file.
seconds must be from 1 to 32767.
repeat must be from 1 to 32767.
OBEY
The OBEY command executes a series of commands entered in an OBEY command file.
Where Issued: Primary or backup system.
Security: Any user.
OBEY [\system.][$volume.][subvolume.]file
OPEN
The OPEN command specifies the RDF control subvolume to which subsequent commands in this
RDFCOM session apply.
Where Issued: Primary or backup system.
Security: Any user.
OPEN control-subvolume
OUT
The OUT command redirects the output of the current RDFCOM session to the specified device or
file.
Where Issued: Primary or backup system.
Security: Any user.
OUT [\system.][$volume.][subvolume.][file]
RESET
The RESET command resets all configuration parameters for the specified process to their default
values within the RDF configuration memory table. The corresponding parameters within the
configuration file do not change, however, unless you issue an ADD command.
Where Issued: Primary system only.
Security: Super-user group member.
RESET {RDF }
{MONITOR }
{EXTRACTOR }
{RECEIVER }
{VOLUME }
{IMAGETRAIL }
{PURGER }
{RDFNET }
{NETWORK }
{TRIGGER }
SET EXTRACTOR
The SET EXTRACTOR command sets the designated configuration parameters for the extractor
process to the supplied values within the RDF configuration memory table. The supplied values are
not applied to the RDF configuration file, however, until you issue an ADD command.
Where Issued: Primary system only.
Security: Super-user group member.
SET EXTRACTOR extractor-option
where extractor-option is:
{CPUS primary-CPU : backup-CPU }
342 RDF Commands Quick Reference