RDF System Management Manual for J-series and H-series RVUs (RDF Update 13)

B Additional Reference Information
This appendix provides additional reference information about:
“Default Configuration Parameters” (page 350)
“Sample Configuration File” (page 351)
“RDFSNOOP Utility” (page 353)
“RDF System Files” (page 354)
“RDF File Codes” (page 355)
Process names are also reserved: $X* , $Y* , and $Z*.
Certain keywords in the NonStop SQL/MP product are reserved words in SQL commands. Those
reserved words are listed in the SQL/MP Reference Manual.
Default Configuration Parameters
This table lists the default values and allowable ranges for RDF configuration parameters.
MAXMINDefault Value(s)Parameter
n.a.n.a.BACKUPSYSTEM value used
on INITIALIZE RDF
RDF BACKUPSYSTEM
n.a.n.a.$0RDF LOGFILE
n.a.n.a.offRDF NETWORK
n.a.n.a.noneRDF OWNER
n.a.n.a.offRDF REPLICATEPURGE
n.a.n.a.$SYSTEM.RDFRDF SOFTWARELOC
10110RDF UPDATERDELAY
n.a.n.a.OFFRDF UPDATERNSASUSPEND
300012400RDF
UPDATERFOPENTHRESHOLD
n.a.n.a.PROTECTEDRDF UPDATEROPEN
3001060RDF UPDATERTXTIME
none060RDF
UPDATERRTDWARNING
n.a.n.a.onRDF USEEXCEPTION
19910165RDFNET PRIORITY
1500:1MONITOR CPUS
19910165MONITOR PRIORITY
1500EXTRACTOR ATINDEX
1500:1EXTRACTOR CPUS
19910165EXTRACTOR PRIORITY
none060EXTRACTOR RTDWARNING
1500RECEIVER ATINDEX
1500:1RECEIVER CPUS
350 Additional Reference Information