RDF System Management Manual for J-series and H-series RVUs (RDF Update 13)

Effect
The command fails.
Recovery
See the Guardian Procedure Errors and Messages Manual for a description and recovery actions
for the file-system error. Correct the error indicated by error#, then, reenter the command.
No image files could be found in the imagetrail on
volume-name.subvolume-name
volume-name
is the name of the image trail’s volume
subvolume-name
is the name of the image trail’s subvolume.
Cause
The COPYAUDIT command could not find any image files on the remote image trail. This problem
indicates that the receiver’s RETAINCOUNT value was probably not set high enough and that,
as a result, some image files on the remote system were purged.
Effect
The COPYAUDIT command aborts.
Recovery
There is no recovery action. The COPYAUDIT command cannot be executed because image
files needed for this command were already purged from the remote system.
No MONITOR is Configured
Cause
The RDF configuration file is invalid.
Effect
The validation fails.
Recovery
Alter the configuration to include the monitor.
No PCB available
Cause
A NEWPROCESS error occurred during START RDF or TAKEOVER processing.
Effect
The command fails.
Recovery
Check system resource utilization. When resources become available, reenter the command.
No RECEIVER is Configured
Cause
The RDF configuration file is invalid.
Effect
The configuration validation fails.
Recovery
Check the receiver parameter entries in the configuration file for invalid values and correct any
errors found.
No VOLUMEs are configured