RDF System Management Manual for J-series and H-series RVUs (RDF Update 13)
Recovery
This is an informational message; no recovery is required.
The total number of items in the INCLUDE, EXCLUDE, INCLUDEPURGE, and
EXCLUDEPURGE lists has exceeded 100.
Cause
The total number of items in the INCLUDE, EXCLUDE, INCLUDEPURGE, and EXCLUDEPURGE
lists, are more than 100.
Effect
The volume is not added for RDF protection.
Recovery
Reduce the total number of items in the INCLUDE, EXCLUDE, INCLUDEPURGE, and
EXCLUDEPURGE lists to less than or equal to 100.
The UPDATER must be a named process
Cause
You must specify a process name for the updater process before issuing an ADD command.
Effect
The start command fails.
Recovery
You must reconfigure RDF with a named updater process.
The year must be greater than 1996.
Cause
You specified the year of a timestamp that is earlier than 1997.
Effect
The command involving the timestamp fails.
Recovery
Reissue the command, specifying a timestamp year that is 1997 or greater.
This aux EXTRACTOR Record already exists.
Cause
You tried to add an EXTRACTOR with a particular ATINDEX value, but there is already one
configured with that value.
Effect
The ADD command fails.
Recovery
Review and revise your RDF configuration.
This aux RECEIVER Record already exists.
Cause
You tried to add an RECEIVER with a particular ATINDEX value, but there is already one
configured with that value.
Effect
The ADD command fails.
Recovery
Review and revise your RDF configuration.
This command is not allowed in an OBEY file.
474 Messages