Safeguard Reference Manual (G06.24+, H06.03+ )

Device and Subdevice Security Commands
Safeguard Reference Manual520618-013
10-32
SHOW DEVICE and SUBDEVICE Commands
OWNER gn, un
is the user ID (group number and member number) of the user who will own this
authorization record if a device or subdevice with these attribute values is added to
Safeguard protection.
WARNING-MODE
{ON|OFF}
is the current warning-mode state of this device or subdevice. ON indicates that
the protection record is in warning mode. The initial value is OFF, which indicates
that warning mode is disabled for this device or subdevice.
AUDIT-ACCESS-PASS = a-spec AUDIT-MANAGE-PASS = a-spec
AUDIT-ACCESS-FAIL = a-spec AUDIT-MANAGE-FAIL = a-spec
are the conditions under which the Safeguard software will audit attempts to
access this device or subdevice and attempts to manage this authorization record.
For more information about these fields for audit-spec, see the SET DEVICE
and SUBDEVICE Commands on page 10-25.
user-spec [DENY] authority-list
is a current default ACL entry for devices. For a full description, see INFO DEVICE
and SUBDEVICE Commands on page 10-19.
[ NO ACCESS CONTROL LIST DEFINED! ]
indicates no default ACL entries are defined. Use SET DEVICE...ACCESS or SET
SUBDEVICE...ACCESS to define default ACL entries. You can use ADD
DEVICE...ACCESS or ADD SUBDEVICE...ACCESS to define ACL entries when
you create an authorization record.
Example
This SHOW DEVICE report displays the current default device attribute values for a
device:
=SHOW DEVICE
Caution. If you do not specify an ACL, only the local super ID can access the device or
subdevice.
TYPE OWNER WARNING-MODE
DEVICE 255,18 OFF
AUDIT-ACCESS-PASS = ALL AUDIT-MANAGE-PASS = NONE
AUDIT-ACCESS-FAIL = ALL AUDIT-MANAGE-FAIL = NONE
033,013 R,W
033,255 R,W
255,018 R,W