SCF Reference Manual for J-Series and H-Series RVUs

SCF Error Messages
SCF Reference Manual for J-Series and H-Series RVUs529649-003
B-41
SCF Error Messages
20340
Cause. The TACL PARAM SCF^PM^LOC includes a system name specification.
Effect. SCF waits for the next command.
Recovery. Exit SCF and retry the TACL PARAM without the system name. Only
$
volume.subvolume
is accepted. Then restart SCF.
20342
Cause. Error
err-num
occurred when trying to do a PROCESS_GETINFOLIST_ on
the Z
subsys
SCF product module.
Effect. SCF waits for the next command.
Recovery. Refer to
Guardian Procedure Calls Reference Manual
for recovery
information about the PROCESS_GETINFOLIST_ error.
20343
Cause. The SCF user library
pmlibname
being used by the Z
subsys
SCF product
module is different from the
scflibname
library being used by SCF. This usually
happens when a product module refers to an SCF user library other than the SCFLIB
file on $SYSTEM.SYSTEM.
Effect. SCF waits for the next command.
Recovery. Perform the following procedure:
1. Exit SCF and run FUP to resecure the Z
subsys
SCF product module file with write
access.
2. Enter a TACL PARAM SCF^LIB^MOVED, YES command.
3. Restart SCF and retry the command that led to the error.
4. Exit SCF and resecure the product module file.
5. Clear the TACL PARAM.
6. Retry the original command that produced this error.
SCF 20340 System name specified. Param SCF^PM^LOC ignored.
SCF 20342 SCF 20342 SCF Product module,
$
volume.subvol
.Z
subsys
SCF, not started,
PROCESS_GETINFOLIST_ error,
err-num
SCF 20343 SCF Product module, $
volume.subvol
.Z
subsys
SCF,
stopped, due to library conflict. SCF library
scflibname
, PM
library
pmlibname
.