SCF Reference Manual for J-Series and H-Series RVUs
SCF Error Messages
SCF Reference Manual for J-Series and H-Series RVUs—529649-003
B-51
Common Error Messages
Effect. SCF terminates.
Recovery. As described under If You Have to Call Your Service Provider on page B-2,
save pertinent information and contact your service provider.
-00030
Cause. An illegal value has been encountered in a supported token.
Effect. SCF terminates.
Recovery. Recovery action depends on the token in error and on the value specified
in that token. Refer to the SCF reference manual for a specific subsystem for
information about recovery from this error by that particular subsystem.
-00031
Cause. A required attribute value has been omitted.
Effect. SCF waits for the next command.
Recovery. Supply the required value and retry the command.
-00032
Cause. A command has been issued in which the version of the command is a higher
level than the version of
subsystem
, and the command contained tokens unknown to
subsystem
. Also, this error can result if the version of a field in an extensible
structured token is a higher level than the version of the named subsystem.
Effect. Communication with that subsystem is not possible. SCF waits for the next
command.
Recovery. Refer to the
SPI Programming Manual
for information about recovery from
version incompatibility. The experienced user may be able to do a VERSION
command and determine what part of the original command can be modified so that
the command can be issued successfully.
subsystem
{E|W}-00030 Internal Error: Invalid Value:
text
(Tnm:
token-number
, Offset:
offset-value
for
object-name.
subsystem {E|W}-00031 Required Value Missing for Attribute:
text
(Tnm:
token-number
, Offset:
offset-value
).
subsystem
{E|W}-00032 Incompatible Version:
version-level-1
,
Command required subsystem to be
version-level-2
for
object-
name.