SCF Reference Manual for J-Series and H-Series RVUs
SCF Error Messages
SCF Reference Manual for J-Series and H-Series RVUs—529649-003
B-53
Common Error Messages
-00037
Cause. The command power level specified on the command is too weak for the state
of named object.
Effect. SCF waits for the next command.
Recovery. Retry the command with a higher command power level, for example,
using the FORCED option.
-00038
Cause. The command power level specified on the command is insufficient to change
the state of the object.
Effect. SCF waits for the next command.
Recovery. Retry the command with a higher command power level, for example,
using the FORCED option.
-00039
Cause. This command does not apply to this object.
Effect. SCF waits for the next command.
Recovery. For a more complete description of all commands that apply to this object
type, see the SCF reference manual for
subsystem
.
-00040
Cause. This command has already been issued against this object, and the object
mentioned is already processing the command.
Effect. SCF waits for the next command.
Recovery. Informational message only; no corrective action is needed.
subsystem
{E|W}-00037 Command power level too weak for the
state of object
object-name.
subsystem
{E|W}-00038 Command power level too weak for the
condition of object
object-name.
subsystem
{E|W}-00039 Command not supported by
object-name.
subsystem
{E|W}-00040 Command in progress for
object-name.