SCF Reference Manual for J-Series and H-Series RVUs
SCF Error Messages
SCF Reference Manual for J-Series and H-Series RVUs—529649-003
B-54
Common Error Messages
-00041
Cause. A process identification number (PIN) is too large for its corresponding data
structure. This occurs when a process running at a high PIN routes a command to a
C-series subsystem by way of the Subsystem Control Process (SCP).
Effect. SCF waits for the next command.
Recovery. Use the SCF ALTER command to reconfigure the process to run at a low
PIN.
-00042
Cause. A specified resource is not available, possibly because of a processor or
network node failure.
Effect. SCF waits for the next command.
Recovery. Informational message only; no corrective action is needed.
-00043
Cause. The backup resource specified in a SWITCH command has not completed
initialization and cannot take over. This can occur immediately following startup of the
backup object.
Effect. SCF waits for the next command.
Recovery. Informational message only; no corrective action is needed.
-00044
Cause. The new resource specified in a SWITCH command does not match the
configured backup resource for the command object. For instance, this error is issued
if a SWITCH command specifying a new processor number of 3 is directed to an object
running in processor 1 with a configured backup of processor 2.
Effect. SCF waits for the next command.
Recovery. Informational message only; no corrective action is needed.
subsystem
{E|W}-00041 Pin Too Big.
subsystem
{E|W}-00042 Resource Not Available.
subsystem
{E|W}-00043 Backup not ready.
subsystem
{E|W}-00044 Switch to Wrong Resource.