ServerNet Cluster Supplement for NonStop NS-Series Servers (H06.03+)

NonStop NS-series Server Supplement
NS-series Servers529933-002
1-4
Hardware Requirements
Hardware Requirements
At least two 6770 switches or 6780 switches (one for the X fabric and one for the Y
fabric) are required. A cable management assembly is required for each 6780 switch.
The switches must be installed and powered on. For Integrity NonStop NS-series
nodes in a layered topology, you can use either the single-mode fiber (SMF) option or
multimode fiber (MMF) option as described in Table 1-2. For example, if you use the
MMF option, you must have MMF PICs installed in both the p-switches and the 6780
switches.
Table 1-2. Integrity NonStop NS-series Node Hardware Requirements
Topology Processor Switches Cluster Switches
Node
Interconnect
Cables
star,
split-star
or
tri-star
topology
Dual SMF PIC in slot 2
of each p-switch
A 6770 switch with at least
one port in the range 0
through 7 must be available
on each ServerNet II Switch
(a subcomponent of the
6770 switch) for connecting
a fiber-optic cable.
SMF cables with
duplex LC
connectors on
one end and
duplex subscriber
connectors (SC)
on the other end
Layered
topology,
SMF
option
Dual SMF PIC in slot 2
of each p-switch
A 6780 switch with a dual
SMF PIC in at least one of
the slots 6 through 9. At
least one port on each PIC in
the range 1 or 2 must be
available.
SMF cables with
duplex LC
connectors on
both ends
Layered
topology
MMF
option
Quad MMF PIC in slot 2
of each p-switch
A 6780 switch with a quad
MMF PIC in at least one of
the slots 6 through 9. At
least one port on each PIC in
the range 1 or 2 must be
available.
For the MMF option, OSM
version T0682AAA is
required on all NonStop
S-Series nodes in the
ServerNet cluster.
MMF cables with
duplex LC
connectors on
both ends