ServerNet Cluster Supplement for NonStop NS-Series Servers (H06.03+)

NonStop NS-series Server Supplement
NS-series Servers529933-002
1-8
INFO CONNECTION Command Display (6770
Switch)
INFO CONNECTION Command Display (6770 Switch)
The syntax for INFO CONNECTION has not changed. Example 1-2, INFO
CONNECTION Display for a 6770 Switch, on page 1-8 shows the display for a 6770
switch connected to an Integrity NonStop NS-series node:
The Node port heading contains information about the p-switch port that connects
to the cluster switch. This port heading replaces the MSEB port heading used for
NonStop S-series nodes.
The NNA Version attribute does not appear in the displays for the Node Port.
Table 1-4 lists the attributes that have different descriptions for Integrity NonStop
NS-series nodes.
Table 1-4. INFO CONNECTION Attributes for Integrity NonStop NS-series Nodes
Attribute Description
Port number The port number on the PIC located in slot 2 of the p-switch to
which the ServerNet cable is attached
PIC Functional ID The type of plug-in card used in the p-switch and cluster switch
Node Routing ID The node routing ID on the p-switch and cluster switch
Example 1-2. INFO CONNECTION Display for a 6770 Switch
INFO CONNECTION X Fabric Y Fabric
|----------------------------------------------------------------------------
| Response Status | ok | ok
| Rsp Status Detail | No Status Detail | No Status Detail
|--------------------|---------------------------|---------------------------
| Switch Type | Model 6770 | Model 6770
|--------------------|---------------------------|---------------------------
| Configuration | Node Port | Switch Port | Node Port | Switch Port
|--------------------|-------------|-------------|-------------|-------------
| Port Info Valid | true | true | true | true
| Port Number | 1 | 0 | 1 | 0
| Desired Port State | n/a | TX/RX Auto | n/a | TX/RX Auto
| Neighbor ID Check | n/a | No Qry pass | n/a | No Qry pass
| Node Number Mask | 0x000fc000 | 0x000fc000 | 0x000fc000 | 0x000fc000
| Node Routing ID | 0x000dc000 | 0x000dc000 | 0x000dc000 | 0x000dc000
| SvNet Node Number | 1 | 1 | 1 | 1
| PIC Functional ID | SMF Optical | SMF Optical | SMF Optical | SMF Optical
|--------------------|-------------|-------------|-------------|-------------