ServerNet Cluster Supplement for NonStop NS-Series Servers (H06.05+)
Integrity NonStop NS-series Server Supplement
ServerNet Cluster Supplement for HP Integrity NonStop NS-Series Servers—529933-003
1-3
Hardware Requirements
Hardware Requirements
At least two 6770 switches or 6780 switches (one for the X fabric and one for the Y
fabric) are required. A cable management assembly is required for each 6780 switch.
The switches must be installed and powered on. For Integrity NonStop NS16000 nodes
in a layered topology, you can use either the single-mode fiber (SMF) option or
multimode fiber (MMF) option as described in Table 1-2. For example, if you use the
MMF option, you must have MMF PICs installed in both the 6780 switches and the
p-switches. Integrity NonStop NS14000 nodes are only supported in a layered topology
using the MMF option.
OSM Service
Connection Suite
T0682H01^AAE*
*T0682H02^AAN
is required for
Integrity NonStop
NS14000 systems
T0682AAA is required on all NonStop S-series
nodes in the cluster if you use a 6780 switch
containing quad MMF PICs in at least one of the
slots 6 through 9 to connect NonStop S-series
servers to the cluster.
Table 1-2. Integrity NonStop NS-series Node Hardware Requirements
Topology
Processor Switches
or ServerNet Switch
Boards* Cluster Switches
Node
Interconnect
Cables
Star,
split-star
or
tri-star
topology
Dual SMF PIC in slot
2 of each p-switch
A 6770 switch with at least one port
in the range 0 through 7 must be
available on each ServerNet II
Switch (a subcomponent of the 6770
switch) for connecting a fiber-optic
cable.
SMF cables with
duplex LC
connectors on
one end and
duplex subscriber
connectors (SC)
on the other end
Layered
topology,
SMF
option
Dual SMF PIC in slot
2 of each p-switch
A 6780 switch with a dual SMF PIC
in at least one of the slots 6 through
9. At least one port on each PIC in
the range 1 or 2 must be available.
SMF cables with
duplex LC
connectors on
both ends
Layered
topology
MMF
option
For Integrity NonStop
NS16000 system:
Quad MMF PIC in slot
2 of each p-switch
For Integrity NonStop
NS14000 system: port
1 of each ServerNet
switch board
A 6780 switch with a quad MMF PIC
in at least one of the slots 6 through
9. At least one port on each PIC in
the range 1 or 2 must be available.
For the MMF option, OSM version
T0682AAA is required on all
NonStop S-Series nodes in the
ServerNet cluster.
MMF cables with
duplex LC
connectors on
both ends
* For Integrity NonStop NS16000 systems, cluster connectivity is done through the processor
switches. For Integrity NonStop NS14000 systems, cluster connectivity is done through the
ServerNet switch boards in the IOAM enclosure.
Table 1-1. Software Requirements for Integrity NonStop
Software Component H-Series PVU G-Series PVU