SNAX/HLS Diagnosis and Support Manual

SNAX/HLS Log Messages
C–4 104706 Tandem Computers Incorporated
process
name
: Continuation of EMS recording from
file
name
of
old
-
collector
Cause. An operator command switched the event collector function for the primary
EMS collector to the collector at which this message appears.
Effect. The event collection functions for the primary EMS collector have been
switched from
old-collector
to another collector (usually identified by an EMS
recording switched to message).
Recovery. Informational message. No action necessary.
process
name
: Continuation of log recording from
name of old log
fil
e
Cause. The logging functions have been switched from the old log file to the file on
which this message appears.
Effect. None.
Recovery. Informational message. No action necessary.
process nam
e
: Customizer error
Cause. This event message typically indicates one of the following conditions:
The customization routine attempted to enlarge an outbound message beyond the
256-byte limit.
The customization initialization routine attempted to allocate memory more than
once.
Effect. SNAX/HLS terminates abnormally.
Recovery. The routines should be corrected and SNAX/HLS should be restarted with
new routines.
process nam
e
: EMS recording on collector-
n
has been stopped
Cause. An operator command terminated event recording to alternate collector
number n (where n can be 1, 2, or 3).
Effect. Event recording to alternate collector number n is terminated.
Recovery. Informational message. No action necessary.