Tandem Failure Data System (TFDS) Manual

EMS Messages and Templates
HP Tandem Failure Data System (TFDS) Manual540122-003
A-12
EMS Messages
6001
Following are the descriptions of the possible tokens in a failure event. name is the
display heading for the token in the event detail.
ZDMP-TKN-CPU-NUM
CPU is the processor number that failed in a processor down incident.
ZDMP-TKN-INCIDENT-NUM
DB Incident Record # is the record number of the incident in the TFDS
Incident Database. (See TFDSCOM REPORT and DETAIL commands).
For event 7000, the incident number is 0 because a record was not created in the
TFDS Incident Database.
ZDMP-TKN-HALT-CODE
Halt-Code is the halt code for a processor down incident. The halt code value
displays in octal.
ZDMP-TKN-INCIDENT-FILENAME
Incident-Filename is the program file that caused the processor down
incident.
ZDMP-TKN-SYMPTOM-STRING
TFDS-Symptom-String is the symptom string of the instrument or processor
down incident. The symptom string consists of the company, product, program,
filename, and error location.
Processor down example: TANDEM.6523.HALT432F.NA.00245
Instrumented subsystem example: HP.TT001H01.TESTn.TSTRTLC.00101
ZDMP-TKN-COMPANY
Company-Name is either:
For an instrument incident, the company name reported by the caller.
For a processor down incident, the company name reported by the program
that halted the processor.
ZDMP-TKN-DESC-TXT1
ZDMP-TKN-DESC-TXT2
ZDMP-TKN-DESC-TXT3
ZDMP-TKN-DESC-TXT4
ZDMP-TKN-DESC-TXT5
Software Error *6001* : Incident Symptom String, Severity n,
Product Number, Program Name, File Name, Error Location