EMS Messages and Templates
HP Tandem Failure Data System (TFDS) Manual540122-003
A-16
EMS Messages
ZDMP-TKN-CLIENT-OSS-PATHNAME
Client-program-OSS-pathname is the OSS pathname for an OSS process
calling an instrument. This token is only for an instrument incident.
ZDMP-TKN-CLIENT-PROCESS-NAME
Client-process-name is the caller's process name. This token is only for an
instrument incident.
ZDMP-TKN-CLIENT-PROC-SEQ-NUM
Client-process-sequence-number is the caller's sequence number. This
token is only for an instrument incident.
ZDMP-TKN-CLIENT-API-TYPE
Client-API-type is the API type of the caller. This token is only for an
instrument incident.
ZDMP-VAL-LEGACY-API 0
ZDMP-VAL-TRIGGER-API 1
ZDMP-VAL-TNS-LEGACY-API 2
ZDMP-TKN-CLIENT-PERSONALITY
Client-personality is the personality of the caller. This token is only for an
instrument incident.
ZDMP-VAL-GUARDIAN-PERSONALITY 0
ZDMP-VAL-OSS-PERSONALITY 1
ZDMP-TKN-CLIENT-CPU
Client-cpu is the processor number where the caller is running. This token is
only for an instrument incident.
ZDMP-TKN-CLIENT-PIN
Client-pin is the pin of the caller. This token is only for an instrument incident.
ZDMP-TKN-CLIENT-OBJ-NAME
Client-obj-name is the program file name of the caller. This token is only for
an instrument incident.
Cause. TFDS issues this event as a result of a halted processor or any failure within
any NonStop operating system subsystem instrumented with the TFDS APIs. The
event detail should specify the actual program that caused the event to be generated.
Effect. Depends on the specific problem and severity. This event is dialed out to your
service provider if the system is so configured.
Recovery. Determine the cause of the failure and take appropriate action.