Tandem Failure Data System (TFDS) Manual
Using TFDSCOM
HP Tandem Failure Data System (TFDS) Manual—540122-003
3-44
TFDSCOM Commands
Helper not running
indicates TFDS helper is not running on this processor.
Helper not responding
indicates a time-out occurred when communicating with the TFDS helper.
Helper on wrong CPU
indicates TFDS helper process name for this processor is running on the
wrong processor.
CPU down
indicates the associated processor is down.
Error text specifying an interface problem with TFDS helper.
Error text returned from TFDS helper.
Examples
TRACEHELPER ALL STOP
TRACEHELPER 1 LEVEL 0x00000002 TO $data1.trcsvol.trac
TRACEHELPER 3 DUMPMEMORYTRACE TO $data1.trcsvol.trc
VERSION
The VERSION command displays revision information about TFDSCOM, TFDS
monitor, and the TFDS helper processes.
Guidelines
•
You can use the abbreviation v in place of VERSION.
•
If the TFDS monitor is not available, an error is reported.
•
If version information is not available from the TFDS helper, one of these
messages is displayed:
Helper not running
indicates the TFDS helper is not running on this processor.
Helper not responding
indicates a time-out occurred when attempting to communicate with the TFDS
helper process.
VERSION