Tandem Failure Data System (TFDS) Manual

EMS Messages and Templates
HP Tandem Failure Data System (TFDS) Manual540122-003
A-7
EMS Messages
Recovery. Ensure that the INSPSNAP program is running in each processor.
46
Cause. The version of the TFDS helper process is older than the version of the trigger
interface.
Effect. Failure incident processing is interrupted.
Recovery. Install the latest versions of TFDS, TFDSHLP and TFDSCOM.
47
Cause. The TFDS helper does not recognize data in the trigger interface. This might
be due to a new TFDS client being run on a system with an older version of TFDSHLP,
or it can be caused by an improperly written client.
Effect. Failure incident processing is interrupted.
Recovery. Ensure that the proper version of TFDSHLP is installed. Contact your
service provider to report that the program file has called TFDS improperly.
48
Cause. The TFDS helper process has determined that the version of the TFDS
monitor is not compatible with the version of the TFDS helper.
Effect. Failure incident processing is interrupted.
Recovery. Check for version inconsistencies between the TFDS monitor and the
TFDS helper. Reinstall TFDS if necessary.
TFDS $ZDMP : Client process xxxxxxxx used a newer trigger
value than is supported by the currently running TFDSHLP.
Please ensure the proper version of TFDS is installed.
TFDS $ZDMP : TFDSHLP client process is using an unknown
trigger value. TFDSHLP is unable to process this incident.
Client Program file: xxxxxxxx Trigger value: nn
TFDS $ZDMP : TFDSHLP is incompatible with the TFDS monitor.
TFDSHLP version: xxxxxxxx