TMF Management Programming Manual (H06.06+, J06.03+)

Table Of Contents
Event Messages
HP NonStop TMF Management Programming Manual540140-010
6-470
Descriptions of Event Messages
538: ZTMF-EVT-HungTxsTimer-Alter
An operator or subsystem control program (SPI requestor) issued an ALTER TMF,
HUNGTXSTIMER command for changing the HUNGTXSTIMER attribute value.
Additional Unconditional Tokens
ZTMF-TKN-EVTHDR-ProcessType
identifies the TMF process that generated the event. The value of this token for this
event is ZTMF-VAL-PROC-TMP.
ZTMF-TKN-HungTxsTimer-Prev
specifies the previous HungTxsTimer value.
ZTMF-TKN-HungTxsTimer
specifies the current HungTxsTimer value.
ZEMS-TKN-Emphasis
is set to False for this event.
Effect
The new attribute value is effective immediately.
Recommended Action
Informative message only; no corrective action is needed.
Additional Unconditional Tokens
ZTMF-TKN-EVTHDR-ProcessType token-type ZSPI-TYP-Enum.
ZTMF-TKN-HungTxsTimer-Prev token-type ZTMF-TYP-Int.
ZTMF-TKN-HungTxsTimer token-type ZTMF-TYP-Int.
ZEMS-TKN-Emphasis token-type ZSPI-TYP-Boolean.
Event-Message Text
The HungTxsTimer is changed from ZTMF-TKN-HungTxsTimer-Prev
to ZTMF-TKN-HungTxsTimer.